Description
Test No. 20
Average fuel consumption – correction factor
The factor follows previous systems, with adjustment range of 750 to 1250. The adjustment method is new for the base cluster. If adjustment is necessary, enter into test 20
using the cluster button. The correction factor number is changed by using the sub-tests
for the “ones, tenths and hundreds of the factor number. The digits will automatically
scroll through 0-9 within each group (ones, tenths, hundreds).
Sub-Tests:
XXX9 20.0 = Press the button when the correct “ones” position is attained.
XX5X 20.1 = Press the button when the correct “tenths” position is attained.
12XX 20.2 = Press the button when the correct “hundreds” position is attained
Test No. 20
BC consumption value correction factor. This test adjusts the correction factor for the
consumption value displayed in the MID. The production line installed value is 1000.
The value ranges from 750 to 1250.
To adjust the correction factor press the trip meter reset button once for a reduction of 1.
For each press of the reset button the value decreases by 1 until it reaches 750. After
750 the number will reset to 1250 and begin to count down again.
To accept the set correction factor press the CC button.
The consumption correction factor (VK) is calculated from the actual amount of consumed fuel (VBR IST) and the displayed value (VBR ANZ):
VK = (Actual MPG / Displayed MPG) X 1000.
Test 20. ? (countdown timer of some sort)
20.0 displays what appears to be a meaningless number
20.1 counts down final digit
20.2 counts down next-to-last digit
20.3 counts down third-to-last digit
20.__
20.00 “ KORR-VERBR (fuel consumption correction factor)
20.01 “ 1er KORR (add 1 to correction factor)
20.02 “ 10er KORR (add 10 to correction factor)
20.03 “ 100er KORR (add 100 to correction factor)
20 Not used
Reviews